196
Use the undo garp timer hold command to restore the default of the GARP Hold timer. This may fail if the
default is beyond the valid value range for the Hold timer.
By default, the Hold timer is 10 centiseconds.
Related commands: display garp timer and garp timer join.
Syntax
garp timer hold timer-value
undo garp timer hold
View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default level
2: System level
Parameter
timer-value: Specifies the Hold timer (in centiseconds), which must be a multiple of 5 and range from 10
(inclusive) to half the Join timer (inclusive).
Example
# Set the GARP Hold timer to 15 centiseconds, assuming that the Join timer is 30 centiseconds.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] garp timer hold 15
garp timer join
Description
Use the garp timer join command to set the GARP Join timer for an Ethernet port, Layer-2 aggregate
interface, or all ports in a port group.
Use the undo garp timer join command to restore the default of the GARP Join timer. This may fail if the
default is beyond the valid value range for the Join timer.
By default, the Join timer is set to 20 centiseconds.
Related commands: display garp timer, garp timer hold, and garp timer leave.
Syntax
garp timer join timer-value
undo garp timer join
View
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default level
2: System level