46
interface loopback
Description
Use the interface loopback command to create a loopback interface or enter loopback interface view.
Use the undo interface loopback command to remove a loopback interface.
Related commands: display interface loopback.
Syntax
interface loopback interface-number
undo interface loopback interface-number
View
System view
Default level
2: System level
Parameter
interface-number: Specifies the loopback interface number, ranging from 0 to 127.
Example
# Create interface loopback 5.
<Sysname> system-view
[Sysname] interface loopback 5
[Sysname-LoopBack5]
interface null
Description
Use the interface null command to enter null interface view.
A device has only one null interface, interface Null 0. Interface Null 0 is always up. You cannot remove
or shut it down.
Related commands: display interface null.
Syntax
interface null 0
View
System view
Default level
2: System level
Parameter
0: Specifies interface Null 0. The null interface number is fixed to 0.

Table of Contents

Other manuals for HP A5830 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A5830 Series and is the answer not in the manual?

HP A5830 Series Specifications

General IconGeneral
BrandHP
ModelA5830 Series
CategorySwitch
LanguageEnglish

Related product manuals