236
service-loopback group
Description
Use the service-loopback group command to create a service loopback group and specify its service
type.
Use the undo service-loopback group command to remove a service loopback group.
A service loopback group can be referenced by other features once it is created, and can process service
traffic only after it is referenced. A service loopback group may be referenced by multiple features at the
same time.
You can change the service type of an existing service loopback group. For the change to be successful,
verify the following conditions:
The service group has not been referenced.
The attributes of all member ports (if any) are not conflicting with the target service type
No service loopback group has been created for the target service type. Only one service loopback
group is allowed for a service type.
You cannot remove a service loopback group that is referenced by other features.
Syntax
service-loopback group number type tunnel
undo service-loopback group number
View
System view
Default level
2: System level
Parameters
number: Specifies the service loopback group ID, ranging from 1 to 1024.
type: Specifies the service type of a service loopback group.
tunnel: Specifies the service type of a service loopback group as Tunnel (unicast tunnel service).
Example
# Configure service loopback group 5 and specify its service type as Tunnel.
<Sysname> system-view
[Sysname] service-loopback group 5 type tunnel