Configuring the switch 154
RMON History Configuration
To display the following form, go to the RMON History Groups Configuration form. Select a History Group, or
open the History folder and click Add History Group.
The following table describes the History Group Configuration controls:
Table 123 History Group Configuration controls
Control Description
History Group ID (1-65535) Configures a numeric identifier for the selected History index.
MIB Object ID Configures the interface MIB Object Identifier.
The interface OID can have a maximum of 127 characters.
Number of Buckets Requested
(1-65535)
Configures the number of requested buckets, which is the number of data slots into which
data is to be saved.
The range is from 1 to 65535. The default is 30.
NOTE: The maximum number of buckets that can be granted is 50.
Polling Interval (1-3600) Configures the time interval over which the data is sampled for each bucket.
The range is from 1 to 3600 seconds. The default value is 1800 seconds.
Owner Enter a text string that identifies the person or entity that uses this History Group.
The owner can have a maximum of 127 characters.

Table of Contents

Other manuals for HP GbE2c - Blc Layer 2/3 Fiber SFP Option

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP GbE2c - Blc Layer 2/3 Fiber SFP Option and is the answer not in the manual?

HP GbE2c - Blc Layer 2/3 Fiber SFP Option Specifications

General IconGeneral
BrandHP
ModelGbE2c - Blc Layer 2/3 Fiber SFP Option
CategorySwitch
LanguageEnglish

Related product manuals