132
Examples
# Display power information for GigabitEthernet 2/0/1.
<Sysname> display poe interface power gigabitethernet 2/0/1
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/0/1 15.0 15.3 15.4 Access Point on Room 509 for Peter
# Display power information for all PIs.
<Sysname> display poe interface power
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/0/25 4.4 4.5 4.6 IP Phone in Room 309 for Peter Smith
GE2/0/26 4.4 4.5 15.4 IP Phone in Room 409 for Peter Pan
GE2/0/27 15.0 15.3 15.4 Access Point in Room 509 for Peter
GE2/0/28 0.0 0.0 0.0 IP Phone in Room 609 for Peter John
GE2/0/29 0.0 0.0 0.0 IP Phone in Room 709 for Jack
GE2/0/30 0.0 0.0 0.0 IP Phone in Room 809 for Alien
--- On State Ports: 3; Used: 23.8(W); Remaining: 776.2(W) ---
Table 24 Command output
Field Description
Interface Interface name of a PI.
CurPower Current power of a PI.
PeakPower Peak power of a PI.
MaxPower Maximum power of a PI.
PD Description Type and location description for the PD connected to a PI.
Ports On Number of PIs that are supplying power.
Used Power consumed by all PIs.
Remaining Total remaining power of the system.
display poe power-usage
Use display poe power-usage to display power usage statistics for PoE power supplies and PSEs.
Syntax
Distributed devices in standalone mode/centralized devices in standalone mode:
display poe power-usage
Distributed devices in IRF mode:
display poe power-usage [ chassis chassis-number ]
Centralized devices in IRF mode
display poe power-usage [ slot slot-number ]
Views
Any view