295
[Sysname] rtm cli-policy test
[Sysname-rmt-test] event cli async mode tab pattern dis inter brief
# Configure a CLI-defined policy to monitor the use of the question mark (?) at command lines that
contain the dis inter brief string. Enable the system to execute a policy-matching command line only if the
actions in the policy are executed successfully when a question mark is entered at the command line.
<Sysname>system-view
[Sysname] rtm cli-policy test
[Sysname-rmt-test] event cli sync mode help pattern dis inter brief
event hotplug
Use event hotplug to configure a hotplug event for a CLI-defined monitor policy.
Use undo event to delete the event in a CLI-defined monitor policy.
Syntax
Distributed devices in standalone mode/centralized devices in standalone or IRF mode:
event hotplug [ insert | remove ] slot slot-number [ subslot subslot-number ]
undo event
Distributed devices in IRF mode:
event hotplug [ insert | remove ] chassis chassis-number slot slot-number [ subslot subslot-number ]
undo event
Default
No hotplug events are configured.
Views
CLI-defined policy view
Predefined user roles
network-admin
Parameters
insert: Specifies the card insert event. EAA executes the policy when card insertion occurs while the
device is operating.
remove: Specifies the card remove event. EAA executes the policy when card removal occurs while the
device is operating.
slot slot-number: Specifies a card by its slot number. (Centralized devices in standalone
mode/distributed devices in standalone mode.)
slot slot-number: Specifies an IRF member device by its member ID. (Centralized devices in IRF mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The chassis-number
argument represents the member ID of the IRF member device. The slot-number argument represents the
slot number of the card. (Distributed devices in IRF mode.)
subslot subslot-number: Specifies a subcard by its subslot number. If you do not specify a subcard, EAA
monitors all subcards for card swapping events.
The following matrix shows the subslot subslot-number option and hardware compatibility:

Table of Contents

Other manuals for HP MSR4080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR4080 and is the answer not in the manual?

HP MSR4080 Specifications

General IconGeneral
BrandHP
ModelMSR4080
CategoryNetwork Router
LanguageEnglish

Related product manuals