139
display poe pse interface power
Use display poe pse interface power to display power information for PIs on a PSE.
Syntax
display poe pse pse-id interface power
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
pse pse-id: Specifies a PSE by its ID.
Usage guidelines
To display PSE ID and slot mappings, use the display poe device command.
Examples
# Display power information for PIs on PSE 7.
<Sysname> display poe pse 7 interface power
Interface Current Peak Max PD Description
(W) (W) (W)
GE2/0/25 4.4 4.5 4.6 IP Phone on Room 309 for Peter Smith
GE2/0/26 4.4 4.5 15.4 IP Phone on Room 409 for Peter Pan
GE2/0/27 15.0 15.3 15.4 Access Point on Room 509 for Peter
GE2/0/28 0.0 0.0 5.0 IP Phone on Room 609 for Peter John
GE2/0/29 0.0 0.0 4.0 IP Phone on Room 709 for Jack
GE2/0/30 0.0 0.0 5.0 IP Phone on Room 809 for Alien
--- On State Ports: 3; Used: 23.8(W); Remaining: 776.2(W) ---
Table 28 Command output
Field Description
Interface Interface name of a PI.
Current Current power of a PI.
Peak Peak power of a PI.
Max Maximum power of a PI.
PD Description Type and location description for the PD connected with a PI.
Ports On Number of PIs that are supplying power.
Used Power consumed by all PIs.
Remaining Remaining power on the PSE.