Parameters
slot slot-number: Specifies an MPU by its slot number. If you do not specify this option, the command
clears kernel thread deadloop information for the active MPU. (Distributed devices in standalone mode.)
slot slot-number: Specifies an IRF member device by its ID. If you do not specify this option, the command
clears kernel thread deadloop information for the master device. (Centralized devices in IRF mode.)
chassis chassis-number slot slot-number: Specifies an MPU on an IRF member device. If you do not
specify this option, the command clears kernel thread deadloop information for the global active MPU.
(Distributed devices in IRF mode.)
cpu cpu-number: Specifies a CPU by its number. (Distributed devices in standalone or IRF
mode/centralized devices in IRF mode.)
Examples
# Clear kernel thread deadloop information.
<Sysname> reset kernel deadloop
Related commands
display kernel deadloop
reset kernel exception
Use reset kernel exception to clear kernel thread exception information.
Syntax
Centralized devices in standalone mode:
reset kernel exception
Distributed devices in standalone mode/centralized devices in IRF mode:
reset kernel exception [ slot slot-number [ cpu cpu-number ] ]
Distributed devices in IRF mode:
reset kernel exception [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies an MPU by its slot number. If you do not specify this option, the command
clears kernel thread exception information for the active MPU. (Distributed devices in standalone mode.)
slot slot-number: Specifies an IRF member device by its ID. If you do not specify this option, the command
clears kernel thread exception information for the master device. (Centralized devices in IRF mode.)
chassis chassis-number slot slot-number: Specifies an MPU on an IRF member device. If you do not
specify this option, the command clears kernel thread exception information for the global active MPU.
(Distributed devices in IRF mode.)
cpu cpu-number: Specifies a CPU by its number.

Table of Contents

Other manuals for HP MSR4080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR4080 and is the answer not in the manual?

HP MSR4080 Specifications

General IconGeneral
BrandHP
ModelMSR4080
CategoryNetwork Router
LanguageEnglish

Related product manuals