HUAWEI NetEngine40E Universal ServiceRouter
Hardware Description
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Panel
Table 6-110 lists the indicators on the panel.
Figure 6-43 Appearance of the 2-Port 40GBase LAN-CFP Integrated Line Processing Unit
(LPUI-101)
Table 6-109 Indicators on the panel of the 2-Port 40GBase LAN-CFP Integrated Line Processing
Unit (LPUI-101)
It is an OFL button. Before removing a board, press the OFL button.
Hold the button for six seconds till the OFL indicator is on. Then, the
board can be pulled out.
If the indicator is steady on, it indicates that you can remove the
board.
If the indicator blinks once every 2s (0.5 Hz), it indicates that the
system is running normally. Otherwise, it indicates that the board fails
to run normally.
If the indicator is steady on, it indicates that the link is normal. If the
indicator blinks, it indicates that data is being transmitted. If the
indicator is off, it indicates that the link is Down.
Interface Attributes
Table 6-110 lists the interface attributes of the 2-Port 40GBase LAN-CFP Integrated Line
Processing Unit (LPUI-101).
Table 6-110 Interface attributes of the 2-Port 40GBase LAN-CFP Integrated Line Processing Unit
(LPUI-101)
Optical
interface
attributes
Compliant with the selected CFP optical module.
Ethernet_II, Ethernet_SAP, and Ethernet_SNAP