6578-D5U Hardware Management Console (HMC)
The HMC is a user interface that provides the functions needed to create and maintain a
multiple-partitioned environment. The interface allows you to directly manipulate HMC-defined objects and
learn more about detected changes in hardware conditions. The HMC also provides service technicians
with diagnostic information for systems that can operate in a multiple-partitioned environment.
Dimensions
Height 140 mm 5.5 in.
Width 425 mm 16.7 in.
Depth 425 mm 16.7 in.
Weight
Minimum 9.4 kg (20 lbs.)
Maximum 11.3 kg (25 lbs.)
Electrical
Power source loading
(typical in kVA)
0.08 kVA to 0.30 kVA (as shipped)
Input Voltage (V ac) 90 V to 265 V ac
Frequency (hertz) 47 to 63 Hz
Thermal output (minimum) 240 Btu/hr. (75 watts)
Thermal output (maximum) 705 Btu/hr. (207 watts)
Maximum altitude 2134 m (7,000 ft.)
Air Temperature
Requirements
Operating Non-Operating
10 to 35°C
(50 to 95°F)
10 to 43°C
(50 to 110°F)
Humidity Requirements Operating Non-Operating
(Noncondensing) 8% - 80% 8% - 80%
Noise Emissions¹ Operating Idle
L
WAd
5.1 bels 4.8 bels
L
pAm
4.3 bels 3.8 bels
<L
pA
>
m
3.7 bels 3.3 bels
Impulsive or prominent
discrete tones
No No
Note: See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
216 Site and Hardware Planning Information