9334 Models 010 and 011 Drawer Expansion Units
Dimensions
Height 171 mm 6.7 in.
(4 EIA units)
Width 443 mm 17.4 in.
Depth 686 mm 27.0 in.
Weight
Minimum 25 kg 55 lbs.
Maximum 43 kg 95 lbs.
Electrical
Power source loading 0.34
(typical in kVA)
Voltage range for
Model 010 (V ac)
200 to 240
Voltage range for
Model 011
200 to 240 V ac or -48 V dc
Frequency (hertz) 50 or 60
Thermal output
(typical)
580 Btu/hr
Power requirements
(typical)
170 watts
Power factor 0.5 to 0.7
Maximum altitude 2135 m (7000 ft.)
Temperature
Requirements
Operating
10 to 40°C
(50 to 104°F)
Non-Operating
10 to 52°C
(50 to 125°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 8 to 80% 5 to 80%
Wet Bulb 27°C (80°F) 27°C (80°F)
Noise Emissions* Operating Idle
L
WAd
5.5 bels 5.2 bels
L
pAm
N/A N/A
<L
pA
>
m
42 dBA 40 dBA
Impulsive or
prominent discrete
tones
No No
* See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
Chapter 10. Physical Characteristics of the 9000 Series 333

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/60000 Series and is the answer not in the manual?

IBM RS/60000 Series Specifications

General IconGeneral
BrandIBM
ModelRS/60000 Series
CategoryServer
LanguageEnglish

Related product manuals