7205 Model 311 External DLT Tape Drive
Dimensions
Height 114 mm 4.8 in.
Width 280 mm 11.0 in.
Depth 292 mm 11.5 in.
Weight
Minimum 6.63 kg 15 lbs.
Maximum 6.63 kg 15 lbs.
Electrical
Power source loading 0.135
(typical in kVA)
Voltage range (V ac) 100 to 127 or 200 to 240 (autoranging)
Frequency (hertz) 50 or 60
Thermal output
(typical)
208 Btu/hr
Power requirements
(typical)
61 watts
Power factor 0.8
Maximum altitude 2135 m (7000 ft.)
Temperature
Requirements
Operating
16 to 32°C
(60 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 20 to 80% 20 to 80%
Wet Bulb 23°C (73°F) 27°C (80°F)
Noise Emissions¹ Operating Idle
L
WAd
5.8 bels 5.5 bels
L
pAm
N/A N/A
<L
pA
>
m
42 dBA 39 dBA
Impulsive or
prominent discrete
tones
No No
Clearances Front Back Left Right
Install/Air Flow² 152mm(6 in) 152mm(6 in) N/A N/A
Service 152 mm(6 in) N/A N/A N/A
Footprint
2
Width
280mm(11 in)
Depth
597mm(23.5 in)
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
290 Site and Hardware Planning Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/60000 Series and is the answer not in the manual?

IBM RS/60000 Series Specifications

General IconGeneral
BrandIBM
ModelRS/60000 Series
CategoryServer
LanguageEnglish

Related product manuals