EasyManuals Logo
Home>IBM>Server>RS/60000 Series

IBM RS/60000 Series User Manual

IBM RS/60000 Series
415 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #324 background imageLoading...
Page #324 background image
7210 Model 005 External CD-ROM Drive
Dimensions
Height 50 mm 1.94 in.
Width 183 mm 7.2 in.
Depth 312 mm 12.3 in.
Weight
Minimum 2.0 kg 4.4 lbs.
Electrical
Power source loading 0.03
(typical in kVA)
Voltage range (V ac) 100 to 125 or 200 to 240 (autoranging)
Frequency (hertz) 50 or 60
Thermal output (max) 50 Btu/hr
Power requirements
(max)
18 watts
Power factor
(minimum)
0.6
Maximum altitude 2135 m (7000 ft.)
Temperature
Requirements
Operating
16 to 32°C
(60 to 90°F)
Non-Operating
10 to 43°C
(50 to 110°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 10 to 80% 10 to 80%
Wet Bulb 23°C (73°F) 27°C (80°F)
Noise Emissions¹ Operating Idle
L
WAd
4.7 bels 4.7 bels
Impulsive or
prominent discrete
tones
No No
Clearances Front Back Left Right
Install/Air Flow N/A N/A N/A N/A
Service 152 mm(6 in) N/A N/A N/A
Footprint
2
Width
183mm(7.2 in)
Depth
464mm(18.3 in)
1. See “Noise Emission Notes” on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
306 Site and Hardware Planning Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/60000 Series and is the answer not in the manual?

IBM RS/60000 Series Specifications

General IconGeneral
BrandIBM
ModelRS/60000 Series
CategoryServer
LanguageEnglish

Related product manuals