7337 Model 360 DLT Tape Library
Dimensions
Height 68.5 cm 27.0 in. (w/casters)
Width 48.1 cm 18.9 in.
Depth 73.5 cm 28.9 in.
Weight
Minimum 65.8 kg 145 lbs.
Maximum 116.6 kg 257 lbs.
Electrical
Power source loading
(kVA)
0.72
Voltage range (V ac) 100 to 240 (autoranging)
Frequency (hertz) 50 or 60
Thermal output 1920 Btu/hr
Power requirements 562 watts
Power factor 0.55 - 0.8
Maximum altitude 2135 m (7000 ft)
Temperature
Requirements
Operating
10 to 38°C
(50 to 100°F)
Non-Operating
5 to 32°C
(40 to 90°F)
Humidity
Requirements
Operating Non-Operating
(Noncondensing) 20 to 80% 20 to 80%
Wet Bulb 26°C (79°F) 46°C (114°F)
Noise Emissions* Operating Idle
L
WAd
6.8 bels 6.6 bels
L
pAm
N/A N/A
<L
pA
>
m
46 dBA 43 dBA
Impulsive or
prominent discrete
tones
No No
* See “Noise Emission Notes” on page 336 for definitions of emissions positions.