Rev. 2.0
Maintenance Guide
2-20
2-7. Replacing the Z-Slide Shaft
When the Z-slide shaft has been replaced, it is necessary to input the MS parameters related to
the θ-axis and Z-axis home position adjustment, Z-axis height, and laser again.
(For details about input items, see section 2-8.)
1) Remove the hollow setscrew c (×1) from the lower portion of the coupling.
2) Detach the Z-slide shaft from the Z-slide bracket.
3) Reassemble the components in the reverse order of disassembly.
Secure the coupling with it kept pushed-in and make sure that any vertical play does not exist
on the slide shaft.
When tightening the setscrews of the coupling, align the flat part of the slide shaft with the
orientation of the coupling setscrew. Tighten the setscrew with a tightening torque of 0.5 Nm.
Figure 2-7-1 Z-slide Shaft
c SM8030312TP
Setscrew M3 L=3
Coupling
40044586
Z-slide Shaft