Maintenance Guide
10-6
10-2. Replacing the Filter Element
1) Put the hand valve located at the lower left portion of the main unit in the close status.
2) Turn the filter element main unit 45( clockwise or counterclockwise to pull it out downward
while lowering the slide part.
3) When replacing the filter element B on the air filter side, turn the resin part fixing the filter
element B counterclockwise to detach it.
4) When replacing the filter element on the micromist separator side, turn the filter element
counterclockwise to detach it.
5) Reassemble the components in the reverse order of disassembly.
CAUTION) Before replacing the filter element, always close the knob of the finger valve.
The filter element must be replaced when it has been used for two years or
when pressure drop reaches 0.1 MPa (1kgf/cm
2
).
Air filter Micromist separator
PF901006000
Filter element B
PF901010000
Filter element
Resin part
Slide part
Figure 10-2-1 Filter Element