Rev. 2.0
Maintenance Guide
5-8
5-6. Replacing the LEFT and RIGHT Sensors
5-6-1. Replacing the LEFT and RIGHT Sensors (M and L Board Specifications)
Bind the cables A and B with binding bands, taking care that they are not pulled or loosened
excessively during adjustment of sensor position.
B
e
e
e
e
c, d
The cable should have an
allowance when the movable
part is moved in the direction
indicated by an arrow mark.
Figure 5-6-1-1 Front Reference: Left Sensor, Rear Reference: Right Sensor