Rev. 2.0
Maintenance Guide
4-6
4-5. Adjusting the Focus
<Procedure>
1) Mount the camera adjustment jig on the top of the CAL block so that the etching surface is
faced downward.
2) Loosen the SEMS cap bolt with washers c and d (total of 6 locations) that secure the
camera, move the camera up and down, and when lines up to 2 on the etching surface are
clearly visible (see the figure below), secure the camera in position.
When the polarizing filter is adjusted to the scale 0 (dark) position, the lines can be seen
easily.
After the adjustment has been completed, return the polarizing filter to the scale 5 (bright)
position.
「2」まわがはっき
見える
カメ
E2106998000
(T110)
Calibration block
c SM6020302UZ (×2)
c SL6041692TN
(×4)
The lines around "2"
shall be seen clearly.
Camera
adjustment jig
E2106998000
(T110)