Maintenance Guide
5-15
5-7-3. Replacing the WAIT, STOP and C-OUT Sensors (XL Board Specifications)
5-7-3-1. Replacing the Fiber
1) Pull out the fiber from the sensor amplifier.
2) To replace the fiber on the light emitting side, detach the light emitting part from the sensor
block. To replace the WAIT or STOP sensor, pull out the fiber from the rail guide.
3) To replace the fiber on the light receiving side, loosen the fiber nut and rotate the fiber itself to
detach it.
4) Reassemble the components in the order of 3) 1).
5) When reassembling the components, adjust the project amount A of the top end of the light
emitting fiber from the sensor block as follows. (Dimension A)
Project amount: A = 6 mm
Figure 5-7-3-1-1 STOP/C-OUT
Sensor Block
Figure 5-7-3-1-2 WAIT Sensor Bracket
40092512 FIBER
6) After the fibers have been replaced, adjust the amplifier as described in 5-7-3-2-2, Attaching
the Amplifier Unit, on the next page.