Maintenance Guide
14-30
[Adjustment items after replacement]
There are no particular adjustment items.
[Replacement timing]
The battery is replaced at reference intervals of three years.
[Replacement procedure]
c Before starting the replacement work, always turn OFF the main power, main circuit
breaker, and main switch.
d The battery unit is located in front of the base frame and on the right side of the ATX power
supply (40048006). Loosen SL6041092TN (2 pc.) to detach the battery unit together with
the ATX_BATTERY BR (40094392).
Additionally, disconnect the cables from the ATX power supply.
e Remove four inch screws (40048047) to detach the battery unit from the ATX_BATTERY
BR.
f Replace the battery unit with a new one. Reassemble the parts and components in the
reverse order of disassembly.