Rev. 2.0
Maintenance Guide
18-4
11) Assemble the lower discharge guide into the new cutter unit for replacement.
12) Assemble the new cutter unit into the machine.
13) Remove the air plug inserted into the cylinder and connect the solenoid valve and cylinder.
Additionally, connect the table connector coming from the machine to the connector on the
cutter unit.
14) For the machine with the fixed bank specifications, assemble the upper discharge guide.
15) After the new cutter unit has been assembled, insert the remaining air plugs into the speed
controller of the cylinder of the removed cutter main unit.