U20-3, U25-3 WSM Hydraulic system (Mechanism section)
IV-M-17
e. Boom anti-fall valve
(1) At neutral position of boom section
The hydraulic oil at port B (cylinder rod side) is shut off.
The hydraulic oil at port A (cylinder bottom side) flows through the passage C and poppet "d" into the
chamber Z. Now the anti-drift poppet gets closed, which prevents the boom from falling.
Section A-A
Section B-B
Port A
Port B
Poppet d
Chamber Z
Passage c
Pb
Pa
Port T