Driving modes
6.5 Installing/removing outrigger beams
6 - 56 3 112 xxx en Operating Manual GMK6300L
xx.xx.xxxx
6.5.6 Disconnecting/establishing the electrical connection
The electrical connection is only present on truck cranes with an outrigger
pressure indicator.
(A) – Disconnecting the connection
• Pull the plugs (1) apart. Protect the plugs
against dirt and moisture.
(B) – Establishing the connection
• Put the plugs (1) together.
• Protect the separating points against dirt
and moisture.
S
Risk of malfunctions in the electronic system!
Always turn off the ignition before you disconnect or establish the electrical
connection. This prevents malfunctions and corresponding error messages
in the subsequent crane operation.