Starting/switching off the engine – for crane operation
10.1 Starting the engine – from the crane cab
Operating Manual GMK6300L 3 112 xxx en 10 - 17
xx.xx.xxxx
10.1.12 Override torque reduction
When the carbamide supply is empty, the torque reduction is activated via
the engine control system.
The monitoring elements are found in the
Warning submenu.
Further information can be found on the
Warning submenu;
à Warning submenu, p. 11 - 110.
– If the carbamide supply falls to the reserve level, then the symbol (1) is
displayed in yellow.
– If the carbamide supply is empty, the symbols (1) and (2) are displayed in
yellow.
– If the symbol (1) flashes, the engine torque is reduced after the next
engine start.
The engine torque is reduced.
• Press the (2) button down to override torque reduction.
The (1) symbol is displayed.
You can override torque reduction up to 3 times.
• Refill with carbamide immediately; à Carbamide, p. 4 - 8.
After the next engine start the torque reduction is deactivated.
The symbol (1) disappears.

Table of Contents

Other manuals for Manitowoc Grove GMK6300L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK6300L and is the answer not in the manual?

Manitowoc Grove GMK6300L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK6300L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals