Malfunctions during crane operation
14.4 Finding and eliminating malfunctions
Operating Manual GMK6300L 3 112 xxx en 14 - 13
xx.xx.xxxx
14.4 Finding and eliminating malfunctions
This section does not include all malfunctions. When a lamp (1) lights up;
à Warning submenu, p. 11 - 110.
14.4.1 Malfunctions on the engine
Malfunction Cause Remedy
Engine does not start –
Starter does not turn
Battery master switch is
switched off
Switch on the battery master
switch;
à p. 10 - 7
Switch the ignition off
à Switch on the ignition, p. 10 - 8
Fuses F1/8, F2/5, F3/8, F4/1
blown
Replace blown fuses;
à p. 14 - 5
Hand-held control connected or
bridging plug not inserted
Disconnect hand-held control or
insert bridging plug;
à p. 12 - 21
Emergency stop switch actu-
ated
à Resetting the emergency stop
switch
, p. 10 - 22
Ignition in the driver's cab
switched on
Switch off the ignition in the
driver's cab;
à p. 4 - 23
Engine does not start –
Starter turns
Batteries insufficiently charged Charge batteries
Fuel tank empty 1. Refuel;
à p. 10 - 4
2. Bleed the fuel system;
à Maintenance Manual
à Separate engine operating
instructions, provided by the manu-
facturer
Air intake inhibitor closed à Releasing the air intake inhibi-
tor
, p. 10 - 23
Symbol
p red Air filter clogged Replace the dry air filter;
à Maintenance Manual
s