5-3
Common Settings
5
Extended Functions – Common Settings –
Setting the Pinch Rollers
This is the setting methods of a pinch roller when detecting the medium.
1
Press the key in LOCAL.
2
Press to select [COMMON SETUP].
3
Press the key twice.
4
Press to select a set value.
• Set value: ON, PWR ON ONLY, PR No. ONLY, OFF
5
Press the key.
6
Press the key several times to end the setting.
Set Value Overview
ON
The pinch roller number and the pinch roller pressure need to be set each time the medium is
set, according to the width of the medium.
PWR ON ONLY
The pinch roller number and the pinch roller pressure need to be set when the medium is set
for the first time after the power is turned ON, according to the width of the medium.
PR No. ONLY
The pinch roller number needs to be set each time the medium is set, according to the width
of the medium.
OFF
The pinch roller setting is not needed when the medium is set.
(The values set with Function are used.)
FUNCT I ON
SETUP <ENT>
FUNCT I ON
COMMON SE TUP <ENT >
PR SETUP
:
ON
PR SETUP
:
PWR ON ON L Y
COMMON SE TUP
PR SETUP <e n t >