Main Body Specifications
8-4
Common Specifications
Item CJV30-60 CJV30-100 CJV30-130 CJV30-160
Maximum printing/cut width 610 mm 1,020 mm 1,361 mm 1,610 mm
Size of a roll
medium
Maximum width 620 mm 1,030 mm 1,371 mm 1,620 mm
Minimum width 100 mm
Thickness 1.0 mm or less
Roll outside diameter
φ180 mm or less
Roll weight
*1
*1. The roll must not sag when its both ends are held.
25 kg or less
Roll inside diameter
2 or 3 inches
Print side Roll exterior surface
Rolling-up
processing
The end of a medium is attached to a paper tube with adhesive tape or weak adhesion.
Size of a leaf
medium
Maximum width 620 mm 1,030 mm 1,371 mm 1,620 mm
Minimum width 100 mm
Distance
accuracy
Absolute accuracy The larger of the two: ± 0.3 mm or ± 0.3% of a specified distance
Reproducibility The larger of the two: ± 0.2 mm or ± 0.1% of a specified distance
Rectangular accuracy ± 0.5 mm / 1,000 mm
Medium skew 5 mm or less every 10 m
Medium cutting
Cutting in the Y direction by the blade installed on the cutter head
(Cutting accuracy (difference between steps): 0.5 mm or less)
Paper ejection
Roll take-up device supplied as a standard accessory (Switchover is possible between
winding up a roll with its printed surface facing inward and outward.)
Interface USB 2.0
Noise
During standby
58 dB or less (FAST-A: 1 m from the front, rear, left, and right sides, and adsorption fan:
low)
Continuous
operation noise
70 dB or less
Safety standards to be met
VCCI-Class A, FCC-Class A, UL 60950, CE Marking (EMC Directive, Low Voltage
Directive), CB Report, and RoHS Directive
Power specifications
AC100 to AC120 ± 10%, AC220 to AC240 ± 10%, 50/60 Hz ± 1 Hz,
15A or less
Power consumption
*2
*2. The main body and the heaters are included.
1,380 W or less
Installation
environment
Allowable
temperature
20°C to 35°C
Relative humidity 35 to 65% Rh (with no dew condensation)
Accuracy-ensuring
temperature
20°C to 25°C
Temperature
gradient
± 10°C/h or less
Dust Equivalent to the normal office level
Weight 110kg 130kg 145kg 160kg
Outside
dimensions
Width 1,524 mm 1,934 mm 2,289 mm 2,538 mm
Depth 739 mm
Height 1,424 mm

Table of Contents

Other manuals for MIMAKI JV5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI JV5 Series and is the answer not in the manual?

MIMAKI JV5 Series Specifications

General IconGeneral
BrandMIMAKI
ModelJV5 Series
CategoryPrinter
LanguageEnglish

Related product manuals