10
LOADING AND INSTALLATION
10.5 Connection and Disconnection of Extension Cable
10 - 33
9
EMC AND LOW
VOLTAGE
DIRECTIVES
10
LOADING AND
INSTALLATION
11
MAINTENANCE AND
INSPECTION
12
TROUBLESHOOTING APPENDICES INDEX
10.5 Connection and Disconnection of Extension Cable
(1) Instructions for handling an extension cable
• Do not stamp an extension cable.
• Be sure to connect the extension cable to the base unit with the base cover
installed to the base unit.
(After you have set the extension number to the extension base unit, reinstall and
screw the base cover.)
• When laying an extension cable, secure 55mm or more as the minimum cable
bend radius.
If it is less than 55mm (2.17 inch), a malfunction may occur due to characteristic
deterioration, cable disconnection or the like.
• When connecting or disconnecting an extension cable, do not hold the ferrite
cores mounted at both ends of the cable.
Hold the connector part of the cable for connection or disconnection.
Holding the ferrite core may cause the cable disconnection in the connector.
Also, if the ferrite core position is shifted, the characteristic will change. When
handling the cable, take care not to shift the ferrite core position.
Diagram 10.32 Connection and Disconnection of Extension Cable
Main base unit
Connector
Extension cable
Ferrite core