6-28
îš‹ Hunting Prevention Function
The hunting prevention function suppresses hunting when the motor is operating with a light load.
If high response has the priority to vibration suppression this function should be disabled (n1-01 = 0).
Related Parameters
Adjusting the Hunting Prevention Gain (n1-02)
Normally it is not necessary to change this setting. Adjust the value under the following circumstances:
• If vibrations occur under light load condition increase the setting.
• If the motor stalls reduce the setting.
Parameter
Number
Name
Setting
Range
Factory
Setting
Change
during
Operation
Access
Level
n1-01 Hunting prevention function selection 0 or 1 1 No A
n1-02 Hunting prevention gain
0.00 to
2.50
1.00 No A