EasyManuals Logo
Home>Siemens>Control Unit>SIMOTION D435-2

Siemens SIMOTION D435-2 Commissioning And Hardware Installation Manual

Siemens SIMOTION D435-2
394 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
Commissioning (software)
6.14 DMC20/DME20 DRIVE-CLiQ hub
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
269
6.14.2 Creating a DMC20/DME20 DRIVE-CLiQ hub
Introduction
A DMC20/DME20 can be inserted directly in the project navigator. The hub is not wired
when you insert the DMC20/DME20 and is displayed in the topology tree in the component
storage. The hub has to be wired manually.
Procedure
1. Right-click "Topology" in the project navigator.
2. Select the "Insert new object" > "DRIVE-CLiQ hub" command from the context menu and
confirm with "OK".
3. Double-click "Topology" to display the topology tree.
In the topology tree, the hub is stored in the component archive.
4. Drag-and-drop the hub to the required DRIVE-CLiQ interface.
The components connected to the hub are displayed in the topology tree.
Result
The added hub is displayed for the "Topology" entry in the project navigator. All components
connected to a hub are also displayed during an automatic configuration.

Table of Contents

Other manuals for Siemens SIMOTION D435-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D435-2 and is the answer not in the manual?

Siemens SIMOTION D435-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D435-2
CategoryControl Unit
LanguageEnglish

Related product manuals