6.14.2 Creating a DMC20/DME20 DRIVE-CLiQ hub
Introduction
A DMC20/DME20 can be inserted directly in the project navigator. The hub is not wired
when you insert the DMC20/DME20 and is displayed in the topology tree in the component
storage. The hub has to be wired manually.
Procedure
1. Right-click "Topology" in the project navigator.
2. Select the "Insert new object" > "DRIVE-CLiQ hub" command from the context menu and
confirm with "OK".
3. Double-click "Topology" to display the topology tree.
In the topology tree, the hub is stored in the component archive.
4. Drag-and-drop the hub to the required DRIVE-CLiQ interface.
The components connected to the hub are displayed in the topology tree.
Result
The added hub is displayed for the "Topology" entry in the project navigator. All components
connected to a hub are also displayed during an automatic configuration.