Connecting
3.10 Routing
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
77
3.10 Routing
Routing describes the cross-network transfer of information from Network x to Network y.
3.10.1 Routing on SIMOTION D
Routing between the different interfaces
The Ethernet interfaces of the D4x5-2
X127 P1 and X130 P1 (for D4x5-2 DP/PN) or
X127 P1, X120 P1 and X130 P1 (for D4x5-2 DP)
each form a separate IP subnet.
The D4x5-2 DP/PN onboard PROFINET IO interface (X150, P1-P3) and the optional second
PROFINET IO interface with CBE30-2 (X1400, P1-P4) also each form a separate IP subnet.
All ports of a PROFINET IO interface always belong to the same IP subnet.
IP routing from IP subnet to IP subnet is not supported. You can use an external IP router
for this
The S7 routing between PROFINET/Ethernet subnets and also to PROFIBUS is possible.
There are therefore the following options for connecting a PG/PC or HMI device to a
SIMOTION D using S7 routing.

Table of Contents

Other manuals for Siemens SIMOTION D435-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D435-2 and is the answer not in the manual?

Siemens SIMOTION D435-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D435-2
CategoryControl Unit
LanguageEnglish

Related product manuals