Commissioning (software)
6.15 TM41 terminal module
SIMOTION D4x5-2
Commissioning and Hardware Installation Manual, 02/2012
271
6.15.2 Configuring TM41 at SINAMICS Integrated
TM41 can be configured after you completed the configuration of SINAMICS Integrated.
Proceed as follows:
1. Double-click "Insert input/output component" at "Input/output component" in the project
navigator.
2. Select TM41 from the "Drive object type" field of the "Insert Input/Output Component"
dialog box and assign a unique name to the module.
3. Confirm your entry with "OK".
The TM41 is inserted in the project navigator by the name you entered.
4. Double-click "Inputs/outputs". The "Inputs/Outputs" property dialog box of TM41 opens.
5. Set "SIMOTION" as the operating mode on the "Pulse encoder emulation" tab, and make
the settings for the emulated sensor signal.
6. Double-click "Configuration" under "SINAMICS_Integrated" in the project navigator and
select the "PROFIdrive message frame" tab.
7. Click "Close" to exit the dialog box.
You have now programmed the TM41 and aligned it with HW Config.

Table of Contents

Other manuals for Siemens SIMOTION D435-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D435-2 and is the answer not in the manual?

Siemens SIMOTION D435-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D435-2
CategoryControl Unit
LanguageEnglish

Related product manuals