Field or control Description
Mark When Sets the mark when condition.
When set to Inside Range or Outside Range, fields are displayed to set a high and low
boundary pattern for the specified search range.
Tap the Binary or Hex field and use the A and B knobs to select and change the values. Or
double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = MAC Length/Type or Client Data.
A, B knob controls Use the A knob to select (highlight) the digit(s) to change.
Use the B knob to change the value of the digit(s).
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
FlexRay serial bus search configuration menu
Use the FlexRay Search configuration menu to define conditions to search for and mark on an FlexRay bus waveform. You can
have multiple searches on the same bus.
NOTE. Requires option SRAUTO.
Field or control Description
Display Enables or disables displaying search marks on this search.
Stop Acquisition if Event
Found
Stops input acquisition when the search event occurs. Default is not enabled.
Source Select the FlexRay bus for which to search.
Mark On Select the type of information for which to search.
Indicator Bits Select the defined indicator bits type for which to search from the drop-down list.
Only available when Mark On = Indicator Bits.
Indicator Bits Enter the indicator bits for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Header Fields.
Identifier Enter the frame identifier pattern for which to search.
Tap the Binary, Hex, or Decimal field and use the A and B knobs to select and change the
values. Or double-tap on the field and use the virtual keypad to enter values.
Only available when Mark On = Frame ID or Header Fields.
Menus and dialog boxes
MSO54, MSO56, MSO58, MSO58LP, MSO64 Help 237