3.1 Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-200))
(1) Install the cleaner and developer unit into the equipment.
Note: Note:
Do not install the toner cartridge.
(2) While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
(3) Key in code [200] and press the [START] button.
The display changes as follows.
Notes:
• A indicates the controlled value of the auto-toner sensor output.
• B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
• C indicates the latest adjustment value.
(4) After about two minutes, the value B automatically starts changing.
100% A A3
TEST MODE
[
0
]
[
5
]
[
POWER
]
230%
B
CA
128
200 A3
128
TEST MODE
[
START
][
200
]
230%
128
200 A3
128
TEST MODE WAIT
04/05

Table of Contents

Other manuals for Toshiba e-STUDIO350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba e-STUDIO350 and is the answer not in the manual?

Toshiba e-STUDIO350 Specifications

General IconGeneral
BrandToshiba
Modele-STUDIO350
CategoryAll in One Printer
LanguageEnglish

Related product manuals