ADJUSTMENT
3 - 26
3.5 Image Quality Adjustment (Scanning Function)
3.5.1 Density adjustment
Adjusts the center density and the variation of density adjustment button.
< Adjustment Mode (05) >
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value. (To correct the keyed-in value, press the [CLEAR] button.)
(4) Press the [ENTER] or [INTERRUPT] button to store the value. The equipment goes back to the
ready state.
(5) Let the equipment restarted and perform scanning job.
(6) If the desired image density has not been attained, repeat step (2) to (5).
Original mode
Item to be adjusted Remarks
Text/Photo Photo Text
845 847 846 Manual density
mode center value
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255
850 852 851 Manual density
mode light step value
The larger the value is, the lighter the light side
becomes.
Acceptable values: 0 to 255
855 857 856 Manual density
mode dark step
value
The larger the value is, the darker the dark side
becomes.
Acceptable values: 0 to 255
860 862 861 Automatic density
mode
The larger the value is, the darker the image
becomes.
Acceptable values: 0 to 255

Table of Contents

Other manuals for Toshiba e-STUDIO350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba e-STUDIO350 and is the answer not in the manual?

Toshiba e-STUDIO350 Specifications

General IconGeneral
BrandToshiba
Modele-STUDIO350
CategoryAll in One Printer
LanguageEnglish

Related product manuals