Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE0 preamble:
Preamble Sys Char - Transmit System Character only.
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
Preamble None - Transmit no preamble (default).
Convert UPCE0 To UPCA - Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A format
before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A
programming selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without conversion
(default - disabled).
UPCE1
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default
- disabled).
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE1 preamble:
Preamble Sys Char - Transmit System Character only.
Preamble Country and Sys Char - Transmit System Character and Country Code (“0” for USA).
Preamble None - Transmit no preamble (default).
Convert UPCE1 To UPCA - Enable this to convert UPCE1 decoded data to UPC-A format before
transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion (default -
disabled).
US Planet (RS507, RS5000 and RS6000 only)
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default
- disabled).
Decode Lengths
The allowable decode lengths are specified by options Length1 and Length2 as follows:
Variable length: Decode symbols containing any number of characters.
Set both Length1 and Length2 to 0.
Range: Decode a symbol with a specific length range (from a to b, including a and b).
Set Length1 to a and set Length2 to b.
Two Discrete Lengths: Decode only symbols containing either of two selected lengths.
Set both Length1 or Length2 to the specific lengths. Length1 must be greater than Length2.
One Discrete Length: Decode only symbols containing a specific length.
Set both Length1 and Length2 to the specific length.
UPC EAN Params
Allows the configuration of the parameters that apply to more than one UPC or EAN decoder.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra WT6000 Series and is the answer not in the manual?

Zebra WT6000 Series Specifications

General IconGeneral
BrandZebra
ModelWT6000 Series
CategoryHandhelds
LanguageEnglish

Related product manuals