Corrective Maintenance
Static Brush
324
14207L-001 A ZM400/ZM600 Maintenance Manual 8/9/07
2. See Figure 186. Remove the two mounting screws securing the static brush assembly.
3. Remove the brush assembly from the printer.
Figure 186 • Remove and Install the Static Brush Assembly)
Install the New Static Brush Assembly
1. See Figure 186. Secure the new static brush assembly to the printer frame with the two
mounting screws previously removed.
2. Reinstall the ribbon and media and close the media cover.
3. Reconnect the AC power cord and data cables.
4. Turn on (l) the printer.
1
Mounting screws (2)
2
Static brush assembly
2
1