Odpravljanje motenj
Climate 5000i – 6721824787 (2021/02)
168
5 Odpravljanje motenj
5.1 Motnje s prikazom
POZOR
Smrtna nevarnost zaradi električnega udara!
V primeru dotika delov pod napetostjo lahko pride do električnega
udara.
Pred deli na električnih komponentah sistema odklopite vse pole
električnega napajanja (varovalka, bremensko stikalo) in preprečite
nenamerni ponovni vklop.
Če se med obratovanjem pojavi motnja, zaslon prikaže kodo motnje
(npr. EH 02).
Če motnja traja več kot 10 minut:
Za kratek čas prekinite napajanje in ponovno vklopite notranjo enoto.
Če motnje ni mogoče odpraviti:
Pokličite pooblaščeni servis ter sporočite kodo motnje in podatke o
napravi.
Tab. 10
Koda motnje Možni vzrok
EC 07 Število vrtljajev ventilatorja zunanje enote je zunaj normalnega območja
EC 51 Motnja parametrov v EEPROMu zunanje enote
EC 52 Motnja temperaturnega tipala na T3 (tuljava kondenzatorja)
EC 53 Motnja temperaturnega tipala na T4 (zunanja temperatura)
EC 54 Motnja temperaturnega tipala na TP (izpustni vod kompresorja)
EC 56 Motnja temperaturnega tipala na T2B (izpust tuljave uparjevalnika; notranje enote s prosto prilagoditvijo)
EH 0A
EH 00
Motnja parametrov v EEPROMu notranje enote
EH 0b Motnja v komunikaciji med glavnim vezjem notranje enote in zaslonom
EH 02 Motnja pri zaznavanju signala ničelnega prehoda
EH 03 Število vrtljajev ventilatorja notranje enote je zunaj normalnega območja
EH 60 Motnja temperaturnega tipala na T1 (sobna temperatura)
EH 61 Motnja temperaturnega tipala na T2 (sredina tuljave uparjevalnika)
EL 0C
1)
1) V sistemu z multi-split klimatsko napravo zaznavanje puščanja ni aktivno.
Ni dovolj hladilnega sredstva ali iztekajoče hladilno sredstvo ali motnja temperaturnega tipala na T2
EL 01 Motnja v komunikaciji med notranjo in zunanjo enoto.
PC 00 Motnja na modulu IPM ali zaščiti pred prekomernim tokom IGBT
PC 01 Zaščita pred prenapetostjo ali podnapetostjo
PC 02 Temperaturna zaščita na kompresorju ali zaščita pred pregrevanjem na modulu IPM ali zaščita pred previsokim tlakom
PC 03 Zaščita pred prenizkim tlakom
PC 04 Motnja na modulu inverterskega kompresorja
PC 08 Zaščita pred preobremenitvijo toka
PC 40 Motnja v komunikaciji med glavnim vezjem zunanje enote in glavnim vezjem pogona kompresorja
−− Konflikt v načinu delovanja notranjih enot; način delovanja notranje in zunanje enote se morata ujemati.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Climate 5000i and is the answer not in the manual?

Bosch Climate 5000i Specifications

General IconGeneral
TypeSplit system
IonizerYes
Multi-splitNo
Display typeLED
Product colorWhite
Gas hose diameter9.52 mm
Hose length (max)25 m
Inverter technology-
Liquid hose diameter6.35 mm
Refrigerating mediumR32
Air conditioner functionsCooling, Dehumidifying, Heating
Cooling capacity (nominal)12000 BTU/h
Refrigerating medium weight620 g
Suitable for room area up to- m²
Cooling capacity in watts (max)4300 W
Cooling capacity in watts (min)1400 W
Heating capacity in watts (max)4400 W
Heating capacity in watts (min)1100 W
Cooling capacity in watts (nominal)3500 W
Cooling energy efficiency (EER, W/W)3.9
Heating energy efficiency (COP, W/W)3.93
Operating temperature (cooling) (T-T)-15 - 50 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Seasonal efficiency rating (cooling) (SEER)8.5
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3810 W
Seasonal efficiency rating (heating) (SCOP) (Warmer heating season)5.8
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.3
Current10 A
AC input voltage220 - 240 V
AC input frequency50 Hz
Design load (cooling)3.3 kW
Energy efficiency scaleA+++ to D
Energy efficiency class (cooling)A+++
Power consumption (cooling) (max)1650 W
Power consumption (cooling) (min)120 W
Power consumption (heating) (max)1480 W
Power consumption (heating) (min)110 W
Annual energy consumption (cooling)136 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Colder heating season)- kW
Design load (heating) (Average heating season)2.6 kW
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Warmer heating season)628 kWh
Annual energy consumption (heating) (Average heating season)847 kWh
Indoor unit typeWall-mountable
Indoor unit depth200 mm
Indoor unit width802 mm
Indoor unit height295 mm
Indoor unit weight8700 g
Cooling airflow (indoor unit)520 m³/h
Indoor unit sound power level60 dB
Indoor unit noise level (low speed)21 dB
Indoor unit noise level (high speed)37 dB
Outdoor unit depth303 mm
Outdoor unit width765 mm
Outdoor unit height555 mm
Outdoor unit weight26400 g
Outdoor unit noise level55 dB
Cooling airflow (outdoor unit)2200 m³/h
Outdoor unit sound power level64 dB

Related product manuals