EasyManuals Logo

Dell PowerConnect 8024 User Manual

Dell PowerConnect 8024
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background image
Managing QSFP Ports 141
8
Managing QSFP Ports
QSFP ports can operate in 1 x 40G mode or in 4 x 10G mode. Appropriate
cables must be used that match the selected mode. When changing from one
mode to another, a switch reboot is required. The QSFP ports also support
stacking over the interfaces in either 1 x 40G or 4 x 10G mode. Changing
from Ethernet mode to stacking mode and vice-versa requires a reboot as
well.
The ports on a QSFP plugin module are named Fo1/1/1-2 in 40-gigabit mode
and Te1/1/1-8 in 10-gigabit mode. On the PC8164, the fixed QSFP ports are
named Fo1/0/1-2 in 40-gigabit mode and Te1/0/49-56 in 10-gigabit mode. All
of the possible populated or configured interfaces will show in the show
interfaces status command regardless of the port mode, i.e. 40-gigabit or
10-gigabit. Unpopulated or unconfigured interfaces for plug in modules do
not show in the show interfaces status command.
The default setting for a 40-gigabit Ethernet interface is nonstacking,
40-gigabit Ethernet (1 x 40G).
The commands to change 1 x 40G and 4 x 10G modes are always entered on
the 40-gigabit interfaces.
The commands to change the Ethernet/stack mode are entered on the
appropriate interface (tengigabitethernet or fortygigabitethernet). It is
possible to configure some of the 10G ports in a 40G interface as stacking and
not others.
To reconfigure a QSFP port, select the 40-gigabit port to change in Interface
Config mode and enter the hardware profile portmode command
with the selected mode. For example, to change a 1 x 40G port to 4 x 10G
mode, enter the following commands on the forty-gigabit interface:
console(config)#interface fo1/1/1
console(config-if-Fo1/1/2)#hardware profile portmode 4x10g
This command will not take effect until the switch is rebooted.
console(config-if-Fo1/1/2)#do reload
Are you sure you want to reload the stack? (y/n)

Table of Contents

Other manuals for Dell PowerConnect 8024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 8024 and is the answer not in the manual?

Dell PowerConnect 8024 Specifications

General IconGeneral
Switching Capacity480 Gbps
StackableYes
Device TypeSwitch
Enclosure TypeRack-mountable
Power RedundancyOptional
Width17.3 in
Height1.7 in
Jumbo Frame SupportYes
Ports24 x 10 Gigabit SFP+
ManagementWeb-based GUI, Command Line Interface (CLI), SNMP
VLAN SupportYes
Power SupplyInternal
Routing ProtocolStatic routing
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Temperature0 to 45 °C
Storage Temperature-20 to 70 °C
Relative Humidity10% to 90% (non-condensing)
MAC Address Table Size32, 000 entries

Related product manuals