892 Configuring DHCP Server Settings
Configuring a Static Address Pool
The commands in this example create an address pool that assigns the
address 192.168.2.10 to the host with a MAC address of 00:1C:23:55:E9:F3.
When this hosts sends a DHCP message requesting network information, the
switch will offer the information configured in this example, which includes a
custom DHCP option to assign the SMTP server IP address.
To configure the switch:
1
Create an address pool named “Tyler PC” and enter into DHCP pool
configuration mode for the pool.
console#configure
console(config)#ip dhcp pool "Tyler PC"
2
Specify the IP addresses that are available in the pool.
console(config-dhcp-pool)#hardware-address
00:1C:23:55:E9:F3
3
Specify the IP address and subnet mask to assign to the client.
console(config-dhcp-pool)#host 192.168.2.10
255.255.255.0
4
Specify the IP address to use as the default gateway.
console(config-dhcp-pool)#default-router
192.168.2.1
5
Specify the primary and secondary DNS servers the hosts will use.
console(config-dhcp-pool)#dns-server
192.168.2.100
console(config-dhcp-pool)#dns-server
192.168.5.101
6
Specify the domain name to be assigned to clients that lease an address
from this pool.
console(config-dhcp-pool)#domain-name
executive.dell.com
7
Specify the option that configures the SMTP server IP address to the host.
console(config-dhcp-pool)#option 69 ip
192.168.1.33
console(config-dhcp-pool)#exit

Table of Contents

Other manuals for Dell PowerConnect 8024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 8024 and is the answer not in the manual?

Dell PowerConnect 8024 Specifications

General IconGeneral
Switching Capacity480 Gbps
StackableYes
Device TypeSwitch
Enclosure TypeRack-mountable
Power RedundancyOptional
Width17.3 in
Height1.7 in
Jumbo Frame SupportYes
Ports24 x 10 Gigabit SFP+
ManagementWeb-based GUI, Command Line Interface (CLI), SNMP
VLAN SupportYes
Power SupplyInternal
Routing ProtocolStatic routing
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Temperature0 to 45 °C
Storage Temperature-20 to 70 °C
Relative Humidity10% to 90% (non-condensing)
MAC Address Table Size32, 000 entries

Related product manuals