EasyManuals Logo

Dell PowerConnect 8024 User Manual

Dell PowerConnect 8024
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
174 Managing a Switch Stack
If a host is in the middle of an exchange with the DHCP server when the
failover occurs, the exchange is interrupted while the control plane restarts.
When DHCP snooping is enabled, the hardware traps all DHCP packets to
the CPU. The control plane drops these packets during the restart. The
DHCP client and server retransmit their DHCP messages until the control
plane has resumed operation and messages get through. Thus, DHCP
snooping does not miss any new bindings during a failover.
As DHCP snooping applies its checkpointed DHCP bindings, IPSG confirms
the existence of the bindings with the hardware by reinstalling its source IP
address filters.
If Dynamic ARP Inspection is enabled on the access switch, the hardware
traps ARP packets to the CPU on untrusted ports. During a restart, the
control plane drops ARP packets. Thus, new traffic sessions may be briefly
delayed until after the control plane restarts.
If IPSG is enabled and a DHCP binding is not checkpointed to the backup
unit before the failover, that host will not be able to send data packets until it
renews its IP address lease with the DHCP server.
NSF and the Storage Access Network
Figure 9-15 illustrates a stack of three PowerConnect switches connecting two
servers (iSCSI initiators) to a disk array (iSCSI targets). There are two iSCSI
connections as follows:
Session A: 10.1.1.10 to 10.1.1.3
Session B: 10.1.1.11 to 10.1.1.1
An iSCSI application running on the stack master (the top unit in the
diagram) has installed priority filters to ensure that iSCSI traffic that is part
of these two sessions receives priority treatment when forwarded in hardware.

Table of Contents

Other manuals for Dell PowerConnect 8024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 8024 and is the answer not in the manual?

Dell PowerConnect 8024 Specifications

General IconGeneral
Switching Capacity480 Gbps
StackableYes
Device TypeSwitch
Enclosure TypeRack-mountable
Power RedundancyOptional
Width17.3 in
Height1.7 in
Jumbo Frame SupportYes
Ports24 x 10 Gigabit SFP+
ManagementWeb-based GUI, Command Line Interface (CLI), SNMP
VLAN SupportYes
Power SupplyInternal
Routing ProtocolStatic routing
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Temperature0 to 45 °C
Storage Temperature-20 to 70 °C
Relative Humidity10% to 90% (non-condensing)
MAC Address Table Size32, 000 entries