744 Configuring L2 Multicast Features
Configuring MLD Snooping Querier
Beginning in Privileged EXEC mode, use the following commands to
configure MLD snooping querier settings on the switch and on VLANs.
ipv6 mld snooping vlan
vlan-id
immediate-leave
Enables MLD snooping immediate-leave mode on the
specified VLAN. Enabling immediate-leave allows the
switch to immediately remove the layer 2 LAN interface
from its forwarding table entry upon receiving an MLD
leave message for that multicast group without first
sending out MAC-based general queries to the interface.
ipv6 mld snooping vlan
vlan-id
mcrtexpiretime
seconds
Specify the multicast router time-out value for to
associate with a VLAN. This command sets the number of
seconds to wait to age out an automatically-learned
multicast router port.
CTRL + Z Exit to Privileged EXEC mode.
show ipv6 mld snooping
vlan
vlan-id
View the MLD snooping settings on the VLAN.
Command Purpose
configure Enter global configuration mode.
ipv6 mld snooping
querier
Enable the MLD snooping querier on the switch.
ipv6 mld snooping
querier vlan
vlan-id
[address
ipv6-address
]
Enable the MLD snooping querier on VLAN specified
with the
vlan-id
parameter.
Use the optional
ip-address
parameter to specify the IP
address that the snooping querier switch should use as the
source address when generating periodic queries.
Command Purpose

Table of Contents

Other manuals for Dell PowerConnect 8024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 8024 and is the answer not in the manual?

Dell PowerConnect 8024 Specifications

General IconGeneral
Switching Capacity480 Gbps
StackableYes
Device TypeSwitch
Enclosure TypeRack-mountable
Power RedundancyOptional
Width17.3 in
Height1.7 in
Jumbo Frame SupportYes
Ports24 x 10 Gigabit SFP+
ManagementWeb-based GUI, Command Line Interface (CLI), SNMP
VLAN SupportYes
Power SupplyInternal
Routing ProtocolStatic routing
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Temperature0 to 45 °C
Storage Temperature-20 to 70 °C
Relative Humidity10% to 90% (non-condensing)
MAC Address Table Size32, 000 entries

Related product manuals