EasyManuals Logo

Dell PowerConnect 8024 User Manual

Dell PowerConnect 8024
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #232 background imageLoading...
Page #232 background image
232 Monitoring and Logging System Information
Configuring Email Alerts for Log Messages
Beginning in Privileged EXEC mode, use the following commands to
configure email alerts so that log messages are sent to the specified address.
Command Purpose
configure Enter Global Configuration mode.
logging email [
severity
] Enable email alerting and determine which non-critical log
messages should be emailed. Including the
severity
value
sets the lowest severity for which log messages are emailed.
These messages are collected and sent in a single email at
the configured log duration.
severity
— (Optional) Enter the number or name of the
severity level for non-critical messages. Log messages at or
above this severity level are emailed. For information about
severity levels, see Table 11-1. Log messages below the
specified level are not emailed.
logging email urgent
{
severity
| none}
Determine which log messages are critical and should be
sent in a single email as soon as they are generated.
severity
— (Optional) Enter the number or name of the
severity level for critical messages. For information about
severity levels, see Table 11-1.
logging email logtime
minutes
Specify how often to send the non-critical email alerts that
have been collected. . The valid range is 30 - 1440 minutes.
logging email message-
type {urgent | non-
urgent | both} to-addr
email-address
Specify the email address of the recipient for log messages.
logging email from-addr
email-address
Specify the email address of the sender, which is the
switch.
logging email message-
type {urgent | non-
urgent | both} subject
subject
Specify the text that will appear in the subject line of email
alerts sent by the switch.

Table of Contents

Other manuals for Dell PowerConnect 8024

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 8024 and is the answer not in the manual?

Dell PowerConnect 8024 Specifications

General IconGeneral
Switching Capacity480 Gbps
StackableYes
Device TypeSwitch
Enclosure TypeRack-mountable
Power RedundancyOptional
Width17.3 in
Height1.7 in
Jumbo Frame SupportYes
Ports24 x 10 Gigabit SFP+
ManagementWeb-based GUI, Command Line Interface (CLI), SNMP
VLAN SupportYes
Power SupplyInternal
Routing ProtocolStatic routing
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z
Operating Temperature0 to 45 °C
Storage Temperature-20 to 70 °C
Relative Humidity10% to 90% (non-condensing)
MAC Address Table Size32, 000 entries