Location 231: Primary Entry Delay
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time a person has from triggering the primary entry/exit zone to entering a valid disarm code
before triggering the alarm. When the entry/exit zone triggers, it automatically disables the follower zones.
There is a secondary entry delay (location 232) for a different entry times.
Format: mmss
Default: 0030
Valid range: 0000 to 5959
Exercise:
Location 232: Secondary Entry Delay
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time a person has from triggering the secondary entry/exit zone to entering a valid disarm code
before triggering the alarm. When the entry/exit zone triggers, it automatically disables the follower zones.
Format: mmss
Default: 0030
Valid range: 0000 to 5959
Keypad Configuration
Each X-Series system can have up to eight LCD or LED keypads controlling it. Keypads can be allocated to
any partition.
To register a keypad:
When a new keypad or after a factory or keypad default, all the keypads LEDs will flash. By pressing
the [#] key the keypad will ask the system for an ID. The first available ID will be given to the keypad.
To clear a keypads ID hold down the 1 and 3 keys while powering the keypad up.
NOTE: By default all keypads, when registered, belong to partition 1.
If a keypad is allocated to a partition without any zones enabled it will display "Not ready."
Location 240: Keypad and Partitions
Location Type: Extended
There is a sub-location for each of the 8 keypads.
Each keypad when registered will belong to partition 1.
Valid range: 1 – 8
Default: 1
Exercise: Add keypad 1 to partition 1, keypad 2 to partition 2, 3 to partition 3 and 4 to 4.
Enter partition 1’s sub-location
Change the 30 sec default to 10sec (mmss)
Now enter the string for each of the keypads and the keypads not installed
leave as default by leaving them in partition 1
[1] [2] [3] [4] [1] [1] [1] [1] [*]
When the [*] key is entered the data will be saved and you will be exited out
of the location