- 23 -
2 Installation
2
Chapter 2 Installation
2.1 Installation of the Servo Drive
2.1.1 Installation Environment Requirements
Installation location
● Install the servo drive inside a cabinet free from sunlight and rain;
● Installtheservodriveinanenvironmentfreefromcorrosiveorinammablegasesorcombustiblegoods,
suchashydrogensulde,chlorine,anmonia,sulphurgas,chloridizegas,acid,sodaandsalt;
● Install the servo drive in an environment free from high temperature, moisture, dust and metal powder;
● Install the servo drive in a place with no vibration;
● Pollutionleveloftheinstallationlocation:PD2.
Figure 2-1 Installation environment
Dust, oil stain
Sunlight
radiation
Strong vibration
Vibration less than
0.6 G
High
temperature
and humidity
Operating ambient temperature
must be kept between 0
−
50℃
Combustible, explosive and
corrosive gases
Combustible
material
May not attach the product to the
surface of flammable objects
Environmental conditions
Item Description
Use in ambient temperature
0–55
℃
(ambient temperature within 40
℃
–55
℃
, and average load ratio not
exceeding 80%) (no freezing)
Use in environment humidity Below 90% RH (no condensation)
Storage temperature –20–+85
℃
(no freezing)
Storage humidity Below 90% RH (no condensation)
Vibration Below 4.9 m/s
2
Impact Below 19.6 m/s
2
IP rating IP20 (except for cable entry)
Altitude Below 1,000 m