- 28 -
2 Installation
2
2.2 Installation of the Servo Motor
2.2.1 Installation Environment Requirements
Installation location
● Installtheservodriveinanenvironmentfreefromcorrosiveorinammablegasesorcombustiblegoods,
suchashydrogensulde,chlorine,anmonia,sulphurgas,chloridizegas,acid,sodaandsalt;
● Usetheservomotorwithoilsealwhenthemotoristobeusedinaplacewithgrindinguid,oilspray,
iron powder or cuttings;
● Install the servo motor away from heat sources such as a heating stove;
● Donotusetheservomotorinanenclosedenvironment.Workinginanenclosedenvironmentwilllead
to a high temperature of the servo motor, which will shorten its service life;
● Noforeignmatterorwaterisallowedintheterminalsinordertonotinuencetheinstallationanduse
of the servo motor.
Environmental conditions
Table 2-1 Installation environment
Item Description
Use in ambient temperature 0–40
℃
(no freezing)
Use in environment humidity 20%–90% RH (no condensation)
Storage temperature –20
℃
–+60
℃
(maximumtemperatureguarantee:72hoursat80
℃
)
Storage humidity 20%–90% RH (no condensation)
Vibration Below 49 m/s
2
Impact Below 490 m/s
2
IP rating
H1andH4:IP67(exceptforthethroughshaftsectionandconnectionterminals
of motor connectors)
Altitude Below 1,000 m (de-rate the drive motor when the altitude is above 1,000 m)