- 68 -
4 Operation Panel
4
4.2 Display of the Operation Panel
● Transition relation between the operation panel display and the host controller operation object
The following mapping relation exists between the function code (decimal) for the panel display and the
operation object dictionary of the host controller (hexadecimal, "Index" and "Sub-index"), and should be
notedinuse:
Objectdictionaryindex=0x2000+functioncodegroupNo.;
Objectdictionarysub-index=hexadecimalofoffsetinfunctioncodegroup+1,forexample:
Operation Panel Display Object Dictionary Operated by the Host Controller
H00-00 2000-01h
H00-01 2000-02h
…… ……
H01-09 2001-0Ah
H01-10 2001-0Bh
…… ……
H02-15 2002-10h
The following section describes content displayed on the operation panel side (decimal) about
operation panel display and parameter setting. The parameters are different from the those
viewedonthehostcontrollerbackground(hexadecimal).Pleasemaketheconversionby
referring to the above table when needed.
● The operation panel can display the running state, parameter, faults, and monitored information Run
settings of the servo drive.
Statedisplay:Displaysthecurrentservodrivestate,suchasservoreadyorrunning;
Parameterdisplay:Displaysthefunctioncodesandtheirsettingvalues;
Faultdisplay:Displaysthefaultandwarningsoccurringintheservodrive;
Monitoringdisplay:Displaysthecurrentrunningparametersoftheservodrive.
AxisNo.display:Displaystheaxisnumbercurrentlyoperatedanddisplayed.
Figure 4-2 Diagram for switching between different display
Power on
Status display
Parameter
display
Monitoring
display
Fault display
Switch to group
H0B
Motor static
Setting function code H
08-32
Auto switch after motor rotating
Axis number
display
MODE
MODE
MODE
MODE
MODE
SET
SEL
SEL
● After the power is on, the operation panel enters the state display mode.
● PresstheMODEkeytoswitchoverbetweendifferentmodes,asshownintheprecedinggure.
● In state display mode, set H02-32 and select the monitored parameters. When the motor rotates, the
operation panel automatically switches over to monitoring display. After the motor stops, the panel auto-
matically restores to the state display.