IPE300 series engineering VFD Function parameter list
-245-
Function
code
Name
Description
Default
Modify
P94.07
Delay time
before brake
switch-on
Hold time before executing brake switch-on
operation.
Range: 0.000–5.000s
0.3s
â—‹
P94.08
Delay time after
brake switch-on
Hold time after executing brake switch-on
operation.
Range: 0.000–5.000s
0.3s
â—‹
P94.09
Brake feedback
exception
detection time
When the brake command and the brake
feedback signal are not consistent, the fault will
be reported after the delay of P94.09.
Range: 0.000–20.000
3.0s
â—‹
P94.10
Electromotive
torque upper limit
at brake
switch-on
Indicates the electromotive torque upper limit at
brake switch-on.
Range: 0.0– 200.0% of the motor rated current
180%
â—‹
P94.11
Braking torque
upper limit at
brake switch-on
Indicates the braking torque upper limit at brake
switch-on.
Range: 0.0– 200.0% of the motor rated current
180%
â—‹