IPE300 series engineering VFD Function parameter list
-198-
P18 group––Status viewing in closed-loop control
Actual frequency
of encoder
Used to indicate the actual-measured encoder
frequency. The value of forward running is
positive; the value of reverse running is
negative.
Range: -999.9–3276.7Hz
Encoder position
count value
Encoder count value, quadruple frequency.
Range: 0–65535
Encoder Z pulse
count value
Corresponding count value of encoder Z pulse.
Range: 0–65535
High-order bit of
position
reference value
It is cleared after stop.
Setting range: 0–30000
Low-order bit of
position
reference value
It is cleared after stop.
Range: 0–65535
High-order bit of
position
feedback value
It is cleared after stop.
Setting range: 0–30000
Low-order bit of
position
feedback value
It is cleared after stop.
Range: 0–65535
Deviation between the reference position and
actual running position.
Setting range: -32768–32767
Position of
position
reference point
Position of reference point of Z pulse when the
spindle stops accurately.
Range: 0–65535
Present position
setting of spindle
Present position setup when the spindle stops
accurately.
Setting range: 0–359.99
Present position
when spindle
stops accurately
Present position when the spindle stops
accurately.
Range: 0–65535
Encoder Z pulse
direction
Z pulse direction display. When the spindle
stops accurately, there may be a couple of
pulses’ error between the position of forward
and reverse orientation, which can be
eliminated by adjusting Z pulse direction of
P20.02 or exchanging phase AB of encoder.
0: Forward
1: Reverse