Grove Published 02-21-2019, Control # 611-05 3-93
TMS9000-2 OPERATOR MANUAL OPERATING CONTROLS AND INDICATORS
AND
• Activate seat switch (2) or either deadman switch (1)
Disabling crane functions
• Activate the rocker switch of the desired crane
function(s) a second time
OR
• De-activate seat switch and deadman switches
All operating elements for crane functions in the
superstructure cab are locked.
Any crane movements are slowed down to standstill within 3
seconds and then locked.
Superstructure cab seat
The seat contact switch is very sensitive. It is recommended
that you also press the dead man's switch in order to avoid
unintentional lockout.
Refer to, Seat contact switch, page 4-40.
Outriggers
NOTE: Outrigger controls are only active when the engine
is turned on and the park brake is set.
Extend/retract outrigger beams, page 3-95.
Extend/retract outrigger jack cylinders, page 3-95.
Right-hand control panel
Button for outrigger preselection
The following functions are pre-selected in the same way
(Figure 3-108).
Left-hand control panel
Retracting/extending outrigger beams pre-selection
The movement stops after the button is released or when an
end position is reached.
In the Outrigger menu
Outrigger span display
To open: Select symbol (1, (Figure 3-110)) and confirm.
1
Left Front beam/Jack Select and Center Front Jack
select
2 Right Front Beam/Jack Select
3 Left Rear Beam/Jack Select
4 Right Rear Beam/Jack Select
1 Press button: Extend pre-selection (Figure 3-109)
2 Press button: Retract pre-selection